Principle
The Canivet Tick-4 Combo Test based on sandwich lateral flow immunochromatographic assay. The test card has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into each sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated Ehrlichia, Borrelia, Anaplasma recombinant antigens and heartworm antibodies respectively. If there are Ehrlichia, Borrelia,
Anaplasma antibodies and Heartworm antigens in the specimen, a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of Ehrlichia, Borrelia, Anaplasma antibodies and Heartworm antigens in the specimen.
TEST PROCEDURE
- - Allow all materials, including specimen and test device, recover to 15-25ºC before running the assay.
- - Take out the test card from the foil pouch and place it horizontally.
- - Place 10 μL of the prepared specimen into the sample hole, matching the window CHW. Then drop 3 drops (approx. 100 μ L) of assay buffer CHW into the sample hole. Start the timer.
-Collect 20 μ L of the prepared specimen into a vial of EHR-ANA-BAB assay buffer and mix well. Then drop 3 drops (approx. 120μL) of the diluted sample into the sample hole "S" of the test card, respectfully matching the windows EHR, ANA, BAB. Start the timer.
- Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.
KIT COMPONENT
- 10×foil pouches, each containing one cassette, one pipette and a desiccant
- 10×assay buffer tubes (1.0 mL each)
- 10×swab sticks
- 1 Product Manual
![Vivatest Ehr Lym Ana Chw Test Ehrlichia Lyme Anaplasma Heartworm Combo Rapid Diagnostic Test](//www.micstatic.com/athena/img/transparent.png)
Item |
Specification |
Product Name |
CCV CPV Ag Test Kit |
Place of Origin |
Zhejiang Province, China |
Brand Name |
OEM |
Model Number |
Cassette |
Properties |
Venerinary Fracture,Diagnosis & Injection |
Type |
Veterinary Products |
Usage |
Animal Disease Detection |
Application: |
Animal Hospital/Home Use/Pet Clinic/Veterinarian |
Specimen |
Canine Fresh Feces |
Assay Time |
5-10 minutes |
Packing |
10pcs/box, 2000pcs/carton |
Shelf Life |
24 months |
Payment |
T/T, Western Union |
Delivery time |
7-15days after payment |
Production Capacity |
1000000pcs/Day |
Storage Temperature |
2-30°C,DO NOT FREEZE. Do not store the test kit in direct sunlight |
Feature
1. Easy opertaion
2. Fast read Result
3. High Sensitivity and accuracy
4. Reasonable price and high quality
![Vivatest Ehr Lym Ana Chw Test Ehrlichia Lyme Anaplasma Heartworm Combo Rapid Diagnostic Test](//www.micstatic.com/athena/img/transparent.png)
1.TEST PROCEDURE
Collect the cat's eye and nasal secretions with a cotton swab. Make the swab well moistened. Note: Collect ocular secretions from the upper and lower eye faces, please avoid discharge from the corners of the eyes. Insert the wet swab into the plastic tube with buffer solution provided and stir to mix well.
2. Place the test plate on a clean, flat surface. Add 2 drops of sample mix (approximately 80 μL) vertically with a dropper to the sample well (S) of the test plate and start timing as shown below.
3. Results are interpreted at 5 minutes and invalidated after 10 minutes.
2.INTERPRETATION OF RESULTS
Positive: The presence of both C band and T band, no matter T band is clear or vague. Negative: Only clear C band appears. Invalid: No colored band appears in C zone, no matter whether T band appears.
3.STORAGE
The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (24 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
4.PRECAUTIONS
For best results, please strictly adhere to these instructions. -All reagents must be placed at room temperature before running the assay. -Do not remove test cassette from its pouch until immediately before use. -Do not reuse the test kit. -Do not use the test beyond its expiration date marked on the foil pouch. -The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.
5.LIMITATION
Vivatest Feline Infectious Peritonitis Ag Test is only an auxiliary tool for determining the FIPV disease. It is used to detect the FIP-triggerred Coronavirus and can only be considered as an in vitro rapid diagnostic reference for veterinarians in practice. FIPV is a complex immunity disorder disease and is very difficult to be detected out by only one method. Vets should also consider about the clinical symptoms in practice and results from other diagnostic tools to give a comprehensive judgement.
Packaging Details 10pcs/ box, 2000boxes/carton
Port of Loading: Shanghai Port
![Vivatest Ehr Lym Ana Chw Test Ehrlichia Lyme Anaplasma Heartworm Combo Rapid Diagnostic Test](//www.micstatic.com/athena/img/transparent.png)
1.How long is the lifespan of your machine?
Ans: We use imported molecular sieve from USA, and the lifespan is more than 18,000 hours.
2. How long is for the warranty period of the machine?
Ans: We provide 12~24 months warranty.
3. What is the sound level of your machine?
Ans:We adopt multilayer noise design,and the sound level is less than 45dba.
4.What certificate do you have?
Our oxygen concentrator have been certificated by CE, ISO certificate.
5.How to clean the filter?
Periodicity routine maintenance is required.
On the back of the unit, there are two filters. First foam filter and secondary air suction filter.
Both filter need to take off and clean once a week. You can wash it with soap and water.Be sure to thoroughly dry the filter
before replacing.
6. Can you provide sample?
Yes, we can provide you sample, but you need to pay for the sample and freight firstly.We will
return the fee after you make an order.If there is any other question pls contact us freely, we will reply you in 24 hours.